Test leads, type K beaded wire thermocouple probes*, carrying case, and a battery.
Key Features
True-rms for accurate AC voltage and current measurements
Built-in infrared thermometer with a laser pointer
Noncontact voltage (NCV) detector for safely checking live electrical current
Data hold and Peak hold
Low impedance (LoZ) function improves accuracy
Low-pass filter blocks environmental noise
Inrush (100 ms) current feature captures start-up current
32 mm (1.25”) jaw size for conductors up to 500 MCM
6000-count backlit LCD
CAT III-600 V safety rating
3 year warranty
More About this Item
The EX623A clamp meter combines a true-rms meter, IR thermometer, thermocouple thermometer, and noncontact voltage detector in one convenient unit. The built-in IR thermometer with a laser pointer has a distance-to-target size ratio of 8:1 to help identify hot spots from a distance. Take temperatures up to 1000 °C (1832 °F) with a type K thermocouple probe. Dual thermocouple inputs measure T1, T2, and T1-T2 differential temperature measurement. A noncontact voltage detector with an LED alert adds a layer of safety for the operator.
Take HVAC flame rod current measurements and capacitance measurements up to 40 mF with the AC/DC µA function. Set the meter to LoZ mode to prevent false readings due to ghost voltage. Activate the low-pass filter to minimize electrical noise to ensure accurate measurements. The meter is safety rated to CAT III-600 V and features rugged, double-molded housing for excellent durability.
*The supplied thermocouple probes are rated for 250 °C (482 °F) max. If a higher temperature is needed, please purchase separate thermocouple probes.
Specifications
DC Min (Volts)0.0001
DC Max (Volts)600
DC Voltage Accuracy600 mV range: ±(0.8% of reading + 2 digits) 6, 60, 600 V ranges: ±(1.5% of reading + 5 digits)
DC Min (amps)1E-05
DC Max (amps)600
DC Current Accuracy40 and 400 V ranges: ±(1.5% of reading + 5 digits) 40.01 to 60.00 A and 400.0 to 600.0 A: ±(2.8% of reading + 5 digits)
AC Min (Volts)0.0001
AC Max (Volts)600
Ac Voltage Accuracy600 mV range: ±(1.0% of reading + 20 digits) 6, 60, and 600 V ranges: ±(2.0% of reading + 5 digits)
AC Min (amps)1E-05
AC Max (amps)600
AC Current Accuracy40 and 400 V ranges: ±(1.5% of reading + 5 digits) 40.01 to 60.00 A and 400.0 to 600.0 A: ±(2.8% of reading + 5 digits)
Resistance Min (Ω)0.1
Resistance Max (MΩ)60
Capacitance Min (nF)0.001
Capacitance Max (mF)40
Capacitance Accuracy6 nF range: ±(5.0% of reading + 30 digits) 60 nF range: ±(5.0% of reading + 20 digits) 600, nF, 6 µF, and 60 µF ranges: ±(3.0% of reading + 5 digits) 600 µF range: ±(4.0% of reading + 10 digits) 6 mF and 40 mF ranges: ±(10.0% of reading + 10 digits)
Frequency Min (Hz)0.1
Frequency Max (Hz)400
Frequency Accuracy±(1% of reading + 3 digits)
Resistivity Accuracy600 Ω range: ±(1.0% of reading + 4 digits) 6, 60, and 600 kΩ ranges: ±(1.5% of reading + 2 digits) 6 MΩ range: ±(2.5% of reading + 3 digits) 60 MΩ range: ±(3.5% of reading + 5 digits)
ContinuityThreshold 50 Ω (test current: < 0.9 mA
Diode TesterTest current: 1.5 mA, typical; Open circuit voltage: 3.2 V DC, typical
Duty Cycle0.5 to 99.0%
True RmsYes
Min Temperature (° F)-58
Max Temperature (° F)1832
Min Temperature (° C)-50
Max Temperature (° C)1000
Temperature Accuracy±(3.0% of reading + 5 °C [9 °F])
Nc Voltage DetectorYes
Count6000
DisplayLarge backlit LCD
Jaw Size32
Safety RatingCAT III 600 V, Pollution Degree 2
PowerOne 9 V battery
Width (in)3.8
Length (in)9.5
Depth (in)1.75
Width (cm)9.6
Length (cm)24.1
Depth (cm)4.5
DescriptionTrue RMS 600 A AC/DC Clamp Meter with IR, Dual Input Type K Thermometer, and NCV